Manufacturer MEAN WELL

XDR-240E-48

Availability: 18 can ship immediately
240 W48 V5 A85V–264V in

Request a Backorder

Submit your request and we will confirm lead time.

XDR-240E-48 SKU: 6943-491

160 more units available on request (ready in 1–2 business days). Contact customer service

Quantity
Quantity Prices (USD)
Quantity
Unit Price (USD)
1+
$51.76 USD
10+
$49.17 USD
20+
$48.14 USD
50+
$47.10 USD
100+
$46.07 USD
200+
$45.03 USD
All prices are displayed in USD. *Import tariff is included in the listed price. You pay exactly what you see—no surprise fees at checkout. Discounts are applied automatically based on the total quantity added to your cart.
Quick Specs
Input Voltage
85V~264V
Output Voltage
48V
Rated Current
5A
Power Rating
240W
Waterproof
Non-waterproof
Dimensions & Weight
4.56 x 1.57 x 4.92 in1.34 lbs

Datasheet (PDF)

If the PDF doesn’t load here, click “Open PDF”.

Features:

  • 85~264Vac input range
  • Global certificates in multi-fields(ITE 62368-1, Industrial 61558-1/-2-16, 61010)
  • 40mm slim width
  • High efficiency up to 95.5% and no-load power dissipation<1.2W
  • Built-in constant current limiting circuit
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Fanless design, cooling by free air convection
  • Overvoltage category III (OVC III)
  • -40°~+70°C wide range operation temperature (>+50°C derating)
  • Operating altitude up to 5000 meters
  • Built-in DC OK relay contact
  • Can be installed on DIN rail TS-35/7.5 or 15
  • 3 years warranty

General Specification

AC input voltage range

85 - 264Vac

AC inrush current (max.)

COLD START 15A /115V 30A/230V

Overload Protection

105~130% rated output power

Hiccup mode when output voltage <30%, recovers automatically after fault condition is removed

Constant current limiting without shutdown within 30%~100% rated output voltage, recovers automatically after fault condition is removed

Over Voltage Protection

(Max. 18V) (Max. 35V) (Max. 50V) (Max. 63V)

Protection type : Hiccup mode, recovers automatically after fault condition is removed

Over temperature Protection

Protection type : Shut down o/p voltage,recovers automatically after temperature goes down

Withstand voltage

I/P-O/P: 4KVac I/P-FG: 2KVac O/P-FG: 1.5KVac O/P-DC OK: 0.5KVac

Working temperature

-40 ~ +70℃ (Refer to "Derating Curve")

Safety standards

UL61010; BS EN/EN62368-1, BS EN/EN61558-1/-2-16, / ; CB IEC62368-1, IEC61558-1, ; TUV BS EN EN61010 IEC61; RCM AS/NZS 61558-1/-2-16;BIS IS13252 (Part 1):2010; BSMI CNS1 -1; CCC GB4943.1; EAC TPTC004 approved; KC KC62368-1 certified no stock ,contact sale for inquires

Dimension (LxWxH)

40*125.2*116mm (W*H*D)

SKU: 6943-491

Similar Models

Same product family and output voltage, with the closest available power ratings.

Same-Day Shipping

Order by 4:00 PM ET, Mon–Fri

Volume Discounts

Save up to 13% on 200+ units

Talk to Our Team

+1 305-432-1030 · Mon–Fri 10–5 ET

No Surprise Fees

What you see is what you pay at checkout

Shipping & delivery

  
 

    Payment & Security

    Questions about shipping or payment? +1 305-432-1030 · sales@htdelectronics.com Mon–Fri 10–5 ET