(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-216
VOLTAGE RANGE
80 ~ 264VAC 113 ~ 370VDC
SETUP, RISE TIME
1000ms, 30ms/230VAC 1500ms, 30ms/115VAC at full load
INRUSH CURRENT (Typ.)
COLD START 40A/115VAC 80A/230VAC
POWER FACTOR
PF>0.95/230VAC PF>0.98/115VAC at full load
OVERLOAD
105 ~ 150% rated output power,
Protection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed
OVERVOLTAGE
(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)
Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover
PROTECTIVE EXTRA-LOW VOLTAGE
IEC/EN61558-2-16 (SELV, 12~48V )
IEC/EN/UL 62368-1 (SELV / ES1,12~48V )
WORKING TEMP.
-40 ~ +80℃ (Refer to "Derating Curve")
SAFETY STANDARDS
CB IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1; TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN60601-1(3.2 Version); UL UL62368-1, ANSI / AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
Dimension (LxWxH)
127x76.2x30.5mm