Passer au contenu
HTD Electronics Entrepôt ouvert
Commandez d’ici --Commandez maintenant expédié Aujourd’hui depuis Miami

24VDC Power Supplies for Industrial Automation and Control Panels

MEAN WELL 24VDC power supplies for PLCs, sensors, actuators and control cabinets: slim DIN rail units from 15 W to 960 W, three-phase input models, DC-UPS and DC-DC modules, and enclosed panel-mount supplies.

  • 24VDCThe standard control voltage for PLC I/O, sensors and relays
  • 15 W – 960 WDIN rail models on this page, single and higher power
  • UL 508 · Class I Div 2Only on the models whose datasheet lists it (see below)
Step 1

Choosing a 24VDC supply for PLCs, sensors and actuators

Add up the continuous current of everything on the 24V bus: PLC CPU and I/O modules, sensors, relays, solenoid valves, HMI and network devices. Then check the inrush or peak current of coils, valves and capacitive loads, and keep 20–30% headroom so the supply runs at about 80% of its rating.

Several series handle short peaks above their rating: for example, the SDR-480 datasheet lists 720 W peak for 3 seconds. Check the PEAK CURRENT line of the datasheet before relying on it.

Total load (W) = sum of device currents (A) × 24 V
Minimum supply (W) = total load ÷ 0.8
Peaks: check inrush of coils and valves against the supply peak rating
Quick 24VDC load calculator
Total load–
Current–
Choose a supply rated at least–

Estimate only. Use the rated current of each device from its manual and check the derating curve in the MEAN WELL datasheet for hot cabinets.

Browse all DIN rail power supplies →

15 – 156 W

DIN rail power supplies by width and wattage

Compact single-phase 24V units for small panels and distribution boxes. HDR has an ultra-slim step shape, MDR is a compact general-purpose series, EDR is the economy line and NDR the slim workhorse for machine panels.

HDR-15-24
HDR-15-24
15 W· 24 V· 0.63 A
$11.63
Shop now
HDR-60-24
HDR-60-24
60 W· 24 V· 2.5 A
$19.70
Shop now
HDR-150-24
HDR-150-24
127.4 W· 24 V· 5.31 A
$40.10
Shop now
MDR-20-24
MDR-20-24
24 W· 24 V· 1 A
$15.45
Shop now
MDR-40-24
MDR-40-24
40.8 W· 24 V· 1.7 A
$20.55
Shop now
MDR-60-24
MDR-60-24
60 W· 24 V· 2.5 A
$20.60
Shop now
MDR-100-24
MDR-100-24
96 W· 24 V· 4 A
$39.98
Shop now
EDR-75-24
EDR-75-24
75 W· 24 V· 3.2 A
$25.49
Shop now
EDR-120-24
EDR-120-24
120 W· 24 V· 5 A
$25.80
Shop now
EDR-150-24
EDR-150-24
156 W· 24 V· 6.5 A
$31.67
Shop now
RND-75-24
RND-75-24
75 W· 24 V· 3.2 A
$27.45
Shop now
NDR-120-24
NDR-120-24
120 W· 24 V· 5 A
$29.65
Shop now

View all HDR models →View all MDR models →View all EDR models →View all NDR models →

240 – 960 W

Higher-power 24VDC DIN rail: 240 W to 960 W

For larger machines and motion panels: NDR, SDR (active PFC, DC OK relay and peak power capability) and the ultra-slim XDR / XDR-E series.

NDR-240-24
NDR-240-24
240 W· 24 V· 10 A
$54.87
Shop now
NDR-480-24
NDR-480-24
480 W· 24 V· 20 A
$103.05
Shop now
SDR-120-24
SDR-120-24
120 W· 24 V· 5 A
$49.85
Shop now
SDR-240-24
SDR-240-24
240 W· 24 V· 10 A
$82.20
Shop now
SDR-480-24
SDR-480-24
480 W· 24 V· 20 A
$149.49
Shop now
XDR-120-24
XDR-120-24
120 W· 24 V· 5 A
$53.42
Shop now
XDR-150E-24
XDR-150E-24
150 W· 24 V· 5.2 A
$27.38
Shop now
XDR-240E-24
XDR-240E-24
240 W· 24 V· 10 A
$51.76
Shop now
XDR-480E-24
XDR-480E-24
480 W· 24 V· 20 A
$100.96
Shop now
XDR-960E-24
XDR-960E-24
960 W· 24 V· 40 A
$241.75
Shop now

View all SDR models →View all XDR-E models →View all DIN rail power supplies →

Input

Single-phase vs three-phase input (WDR, TDR, XTR)

Most panels feed the 24V supply from a single-phase 100–240 VAC circuit. If the cabinet only has a 400/480 VAC three-phase supply, or the 24V load is large, use a wide-input or three-phase model:

  • WDR: 180–550 VAC input on the models below, for panels without a neutral or 120/230 V tap (check the wiring diagram in the datasheet).
  • TDR: three-phase 340–550 VAC input (TDR-480 datasheet, dual-phase operation possible).
  • XTR: three-phase 320–600 VAC wide-range input (dual-phase operation possible), for 480 W and 960 W loads.
WDR-120-24
WDR-120-24
120 W· 24 V· 5 A
$63.72
Shop now
WDR-240-24
WDR-240-24
240 W· 24 V· 10 A
$119.89
Shop now
XTR-480-24
XTR-480-24
480 W· 24 V· 20 A
$118.40
Shop now
XTR-960-24
XTR-960-24
960 W· 24 V· 40 A
$228.10
Shop now
TDR-480-24
TDR-480-24
480 W· 24 V· 20 A
Request a quote

View all WDR models →View all TDR models →View all XTR models →

Uptime

Redundancy and parallel operation

Two ways to keep a 24V bus running when one supply fails or you need more power:

N+1

Redundancy module

Two supplies feed a redundancy module such as the DR-RDN20 (two 21–28 V inputs, 20 A per input, input OK LEDs). If one supply fails, the other carries the load.

DIN rail peripherals →

Parallel

Current sharing

Only connect supplies in parallel when the datasheet allows it. For example, the DDR-240 datasheet allows up to 4 units in parallel and current sharing up to 960 W (3+1).

DDR series →

Ask us

Larger systems

DRP-3200 rack-mountable front end rectifier systems are quoted per project. Tell us the load, redundancy level and input.

Request a quote →

Backup

DC-UPS and battery backup in panels

A DC-UPS keeps the PLC, HMI and network alive through short outages. The DRS-240 combines a 24V supply, battery charger and DC UPS function, with AC fail and battery low signals for the PLC. DRC and DR-UPS series are available by quote.

Battery-fed panels can use a DIN rail DC-DC converter: DDR-120A-24 runs from a 12V battery (9–18 V input) and DDR-240C-24 from a 48V battery (33.6–67.2 V input).

DRS-240-24
DRS-240-24
240 W· 24 V· 10 A
$185.14
Shop now
DDR-120A-24
DDR-120A-24
100.8 W· 24 V· 4.2 A
$63.85
Shop now
DDR-240C-24
DDR-240C-24
240 W· 24 V· 10 A
$116.98
Shop now

View all DRC models →View all DRS models →View all DDR models →

Panel mount

Enclosed panel-mount alternatives (LRS, RSP, UHP)

When there is back-panel space instead of DIN rail, enclosed supplies give more watts per dollar. LRS covers 35 W to 1200 W, RSP adds PFC for higher-power panels, and the slim UHP series is available by quote.

LRS-50-24
LRS-50-24
52.8 W· 24 V· 2.2 A
$11.07
Shop now
LRS-75-24
LRS-75-24
76.8 W· 24 V· 3.2 A
$13.81
Shop now
LRS-100-24
LRS-100-24
108 W· 24 V· 4.5 A
$13.99
Shop now
LRS-150-24
LRS-150-24
156 W· 24 V· 6.5 A
$17.88
Shop now
LRS-200-24
LRS-200-24
211.2 W· 24 V· 8.8 A
$26.90
Shop now
LRS-350-24
LRS-350-24
350.4 W· 24 V· 14.6 A
$25.68
Shop now
LRS-450-24
LRS-450-24
451.2 W· 24 V· 18.8 A
$55.48
Shop now
LRS-600-24
LRS-600-24
600 W· 24 V· 25 A
$56.45
Shop now
LRS-1200-24
LRS-1200-24
1200 W· 24 V· 50 A
$148.43
Shop now
RSP-320-24
RSP-320-24
320 W· 24 V· 13.4 A
$52.57
Shop now

View all LRS models →View all RSP-75~500 models →View all UHP models →

Certifications to look for

ListingWhat it coversSeries on this page whose datasheet lists it
UL 508Industrial control equipmentHDR-15, HDR-60, MDR, EDR, NDR, SDR, WDR, TDR-480
UL 61010-1Electrical equipment for measurement, control and lab useHDR-150, XDR / XDR-E
Class I, Division 2Hazardous locations (North America)MDR-40, MDR-60, XDR-120
SEMI F47Voltage sag immunity (semiconductor tools)SDR-120, SDR-240, SDR-480, XDR-120
UL 62368-1Audio/video and IT equipment safetyLRS, RSP-320, DRS-240, DDR

Listings are taken from each series datasheet and can vary by model and output voltage. Always confirm on the datasheet linked from the product page.

Compare 24V DIN rail series

Series24V power (models on this page)AC input (product specs)Best for
HDR15–127 W85–264 VACSlim step shape for distribution boxes
MDR24–96 W85–264 VACCompact general-purpose panels
EDR75–156 W90–264 VACEconomy single-phase
NDR75–480 W90–264 VACSlim machine panels
SDR120–480 W88–264 VACPFC, peak power, DC OK relay
XDR / XDR-E120–960 W85–305 VAC (XDR-120)Ultra slim, high power
WDR120–240 W180–550 VAC400/480 VAC panels

Figures are for the 24V models listed on this page. Confirm full specs on the datasheet linked from each product page.

24VDC power supply FAQs

What size 24VDC power supply do I need for a PLC?

Add the continuous current of the PLC, I/O, sensors and outputs, multiply by 24 V and divide by 0.8. Example: 0.5 A CPU + 1.5 A I/O + 1 A sensors + 2 A valves = 5 A × 24 V = 120 W, so choose at least 150 W, such as the EDR-150-24 or XDR-150E-24. Check inrush of coils and valves against the supply peak rating.

What's the difference between NDR, SDR, EDR and HDR?

HDR is ultra slim with a step shape for distribution boxes (15–150 W). EDR is the economy line. NDR is a slim general-purpose series up to 480 W. SDR has active PFC, a DC OK relay and peak power capability for demanding loads. All four are DIN rail mount; see the comparison table above.

Can I connect two DIN rail power supplies in parallel for redundancy?

For redundancy, use a redundancy module such as the DR-RDN20 between two supplies, so one can fail without dropping the 24V bus. Connect outputs directly in parallel only when the datasheet allows it, for example the DDR-240 (up to 4 units).

Do I need a three-phase DIN rail power supply?

Only if the cabinet has no single-phase supply or you need a large 24V load from a 400/480 VAC feed. WDR models accept 180–550 VAC, and the TDR-480 datasheet lists three-phase 340–550 VAC input.

How do I add battery backup (DC-UPS) to a control panel?

Use a supply with a DC UPS function such as the DRS-240-24, which charges the battery and switches to it when AC fails, and sends AC fail and battery low signals to the PLC. Size the battery for the backup time you need.

What does Class I Division 2 mean for a power supply?

It is a North American hazardous-location classification for areas where flammable gases or vapors are present only under abnormal conditions. Use only models whose datasheet lists it, such as the MDR-40, MDR-60 and XDR-120 on this page.

24V vs 12V vs 48V in automation, which should I use?

24VDC is the standard for PLC I/O, sensors and relays. 12V suits small panels and some instruments. 48V halves the current of 24V for the same power, which helps with long cable runs and higher-power drives.

Need help choosing?

Send us your panel load list (current per device and input voltage) at sales@htdelectronics.com, or request a quote for project quantities.