{"title":"ITE\/ Medical\/ Household\/ Industrial - Low Profile PCB Type","description":"","products":[{"product_id":"lop-600-54","title":"LOP-600-54","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(12V: 30.5mm, 15 - 54V: 33.5mm)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e400W convection, 600W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(12V: 127x76.2x35mm) (15-54V: 127x76.2x33.5mm)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447338549415,"sku":null,"price":139.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-600-54-600w-53-low-profile-open-frame-power-supply-54v-5088452.jpg?v=1780496654"},{"product_id":"lop-600-48","title":"LOP-600-48","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(12V: 30.5mm, 15 - 54V: 33.5mm)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e400W convection, 600W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(12V: 127x76.2x35mm) (15-54V: 127x76.2x33.5mm)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447338811559,"sku":null,"price":139.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-600-48-600w-53-low-profile-open-frame-power-supply-48v-3510398.jpg?v=1780496654"},{"product_id":"lop-600-36","title":"LOP-600-36","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(12V: 30.5mm, 15 - 54V: 33.5mm)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e400W convection, 600W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(12V: 127x76.2x35mm) (15-54V: 127x76.2x33.5mm)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447339040935,"sku":null,"price":139.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-600-36-600w-53-low-profile-open-frame-power-supply-36v-2330743.jpg?v=1780496657"},{"product_id":"lop-600-27","title":"LOP-600-27","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(12V: 30.5mm, 15 - 54V: 33.5mm)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e400W convection, 600W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(12V: 127x76.2x35mm) (15-54V: 127x76.2x33.5mm)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447339303079,"sku":null,"price":139.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-600-27-600w-53-low-profile-open-frame-power-supply-27v-7025244.jpg?v=1780496658"},{"product_id":"lop-600-24","title":"LOP-600-24","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(12V: 30.5mm, 15 - 54V: 33.5mm)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e400W convection, 600W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(12V: 127x76.2x35mm) (15-54V: 127x76.2x33.5mm)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447339565223,"sku":null,"price":139.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-600-24-600w-53-low-profile-open-frame-power-supply-24v-1049352.jpg?v=1780496659"},{"product_id":"lop-600-18","title":"LOP-600-18","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(12V: 30.5mm, 15 - 54V: 33.5mm)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e400W convection, 600W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(12V: 127x76.2x35mm) (15-54V: 127x76.2x33.5mm)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447339794599,"sku":null,"price":139.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-600-18-600w-53-low-profile-open-frame-power-supply-18v-2381420.jpg?v=1780496661"},{"product_id":"lop-600-15","title":"LOP-600-15","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(12V: 30.5mm, 15 - 54V: 33.5mm)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e400W convection, 600W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(12V: 127x76.2x35mm) (15-54V: 127x76.2x33.5mm)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447340089511,"sku":null,"price":139.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-600-15-600w-53-low-profile-open-frame-power-supply-15v-7275043.jpg?v=1780496662"},{"product_id":"lop-600-12","title":"LOP-600-12","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(12V: 30.5mm, 15 - 54V: 33.5mm)\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e400W convection, 600W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(12V: 127x76.2x35mm) (15-54V: 127x76.2x33.5mm)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447340384423,"sku":null,"price":139.27,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-600-12-600w-53-low-profile-open-frame-power-supply-12v-1749791.jpg?v=1780496665"},{"product_id":"lop-500-54","title":"LOP-500-54","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (30.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e320W convection, 500W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x30.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447340581031,"sku":null,"price":129.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-500-54-500w-53-low-profile-open-frame-power-supply-54v-177909.jpg?v=1780496668"},{"product_id":"lop-500-48","title":"LOP-500-48","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (30.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e320W convection, 500W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x30.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447340843175,"sku":null,"price":129.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-500-48-500w-53-low-profile-open-frame-power-supply-48v-444372.jpg?v=1780496668"},{"product_id":"lop-500-36","title":"LOP-500-36","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (30.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e320W convection, 500W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x30.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447341039783,"sku":null,"price":129.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-500-36-500w-53-low-profile-open-frame-power-supply-36v-846365.jpg?v=1780496670"},{"product_id":"lop-500-27","title":"LOP-500-27","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (30.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e320W convection, 500W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x30.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447341301927,"sku":null,"price":129.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-500-27-500w-53-low-profile-open-frame-power-supply-27v-854312.jpg?v=1780496671"},{"product_id":"lop-500-24","title":"LOP-500-24","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (30.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e320W convection, 500W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x30.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447341564071,"sku":null,"price":129.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-500-24-500w-53-low-profile-open-frame-power-supply-24v-178889.jpg?v=1780496674"},{"product_id":"lop-500-18","title":"LOP-500-18","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (30.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e320W convection, 500W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x30.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447341793447,"sku":null,"price":129.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-500-18-500w-53-low-profile-open-frame-power-supply-18v-337996.jpg?v=1780496674"},{"product_id":"lop-500-15","title":"LOP-500-15","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (30.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e320W convection, 500W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x30.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447342416039,"sku":null,"price":129.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-500-15-500w-53-low-profile-open-frame-power-supply-15v-438124.jpg?v=1780496675"},{"product_id":"lop-500-12","title":"LOP-500-12","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (30.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e320W convection, 500W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x30.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447342710951,"sku":null,"price":129.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-500-12-500w-53-low-profile-open-frame-power-supply-12v-693452.jpg?v=1780496676"},{"product_id":"lop-400-54","title":"LOP-400-54","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (27.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e250W convection, 400W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x27.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447343497383,"sku":null,"price":108.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/74981985_d8fa1854-081a-4234-a143-0e08f8b6d67f.jpg?v=1780496678"},{"product_id":"lop-400-48","title":"LOP-400-48","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (27.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e250W convection, 400W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x27.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447344021671,"sku":null,"price":108.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/74981985_aa203bf3-33f5-4ee4-b9d8-de1d3d6bafc0.jpg?v=1780496680"},{"product_id":"lop-400-36","title":"LOP-400-36","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (27.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e250W convection, 400W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x27.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447344382119,"sku":null,"price":108.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/74981985_292bcd13-2efd-49de-8f17-d42a90aad522.jpg?v=1780496680"},{"product_id":"lop-400-27","title":"LOP-400-27","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (27.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e250W convection, 400W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x27.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447344644263,"sku":null,"price":108.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/74981985_9dec1452-6a41-4635-bfe0-35a25e45876c.jpg?v=1780496682"},{"product_id":"lop-400-24","title":"LOP-400-24","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (27.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e250W convection, 400W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x27.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447345397927,"sku":null,"price":108.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/74981985_323657eb-e820-49f0-9ea3-6aa147f7b048.jpg?v=1780496684"},{"product_id":"lop-400-18","title":"LOP-400-18","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (27.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e250W convection, 400W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x27.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447345758375,"sku":null,"price":108.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/74981985_3a9e94d3-b9bb-4a82-ac33-44e07a23098d.jpg?v=1780496687"},{"product_id":"lop-400-15","title":"LOP-400-15","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (27.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e250W convection, 400W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x27.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447346577575,"sku":null,"price":108.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/74981985_13c6f2df-76f2-493e-a256-7049b4ae6ae4.jpg?v=1780496684"},{"product_id":"lop-400-12","title":"LOP-400-12","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e5\"x3\" compact size with low profile (27.5mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e(ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e250W convection, 400W with FAN 23CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 95%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e127x76.2x27.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447346774183,"sku":null,"price":108.17,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/74981985.jpg?v=1780496685"},{"product_id":"lop-300-54","title":"LOP-300-54","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e180W convection, 300W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447347069095,"sku":null,"price":70.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-300-54-300w-42-low-profile-open-frame-power-supply-54v-988994.jpg?v=1780496686"},{"product_id":"lop-300-48","title":"LOP-300-48","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e180W convection, 300W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447347560615,"sku":null,"price":70.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-300-48-300w-42-low-profile-open-frame-power-supply-48v-276329.jpg?v=1780496687"},{"product_id":"lop-300-36","title":"LOP-300-36","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e180W convection, 300W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447348117671,"sku":null,"price":70.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-300-36-300w-42-low-profile-open-frame-power-supply-36v-777931.jpg?v=1780496687"},{"product_id":"lop-300-30","title":"LOP-300-30","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e180W convection, 300W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447348641959,"sku":null,"price":70.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-300-30-300w-42-low-profile-open-frame-power-supply-27v-330510.jpg?v=1780496688"},{"product_id":"lop-300-27","title":"LOP-300-27","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e180W convection, 300W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447349133479,"sku":null,"price":70.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-300-27-300w-42-low-profile-open-frame-power-supply-27v-618603.jpg?v=1780496689"},{"product_id":"lop-300-24","title":"LOP-300-24","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e180W convection, 300W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447349690535,"sku":null,"price":70.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-300-24-300w-42-low-profile-open-frame-power-supply-24v-927388.jpg?v=1780496690"},{"product_id":"lop-300-18","title":"LOP-300-18","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e180W convection, 300W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447350280359,"sku":null,"price":70.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-300-18-300w-42-low-profile-open-frame-power-supply-18v-453241.jpg?v=1780496691"},{"product_id":"lop-300-15","title":"LOP-300-15","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e180W convection, 300W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447350739111,"sku":null,"price":70.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-300-15-300w-42-low-profile-open-frame-power-supply-15v-229531.jpg?v=1780496692"},{"product_id":"lop-300-12","title":"LOP-300-12","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e180W convection, 300W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447351099559,"sku":null,"price":70.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-300-12-300w-42-low-profile-open-frame-power-supply-12v-272741.jpg?v=1780496693"},{"product_id":"lop-200-54","title":"LOP-200-54","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e140W convection, 200W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447351591079,"sku":null,"price":64.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-200-54-200w-42-low-profile-open-frame-power-supply-54v-894501.jpg?v=1780496695"},{"product_id":"lop-200-48","title":"LOP-200-48","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e140W convection, 200W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447351951527,"sku":null,"price":64.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-200-48-200w-42-low-profile-open-frame-power-supply-48v-258231.jpg?v=1780496694"},{"product_id":"lop-200-36","title":"LOP-200-36","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e140W convection, 200W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447352475815,"sku":null,"price":64.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-200-36-200w-42-low-profile-open-frame-power-supply-36v-987259.jpg?v=1780496696"},{"product_id":"lop-200-27","title":"LOP-200-27","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e140W convection, 200W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447352934567,"sku":null,"price":64.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-200-27-200w-42-low-profile-open-frame-power-supply-27v-911715.jpg?v=1780496697"},{"product_id":"lop-200-24","title":"LOP-200-24","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e140W convection, 200W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447353295015,"sku":null,"price":64.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-200-24-200w-42-low-profile-open-frame-power-supply-24v-354005.jpg?v=1780496699"},{"product_id":"lop-200-18","title":"LOP-200-18","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e140W convection, 200W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447354081447,"sku":null,"price":64.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-200-18-200w-42-low-profile-open-frame-power-supply-18v-231935.jpg?v=1780496699"},{"product_id":"lop-200-15","title":"LOP-200-15","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e140W convection, 200W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type : Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447355457703,"sku":null,"price":64.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-200-15-200w-42-low-profile-open-frame-power-supply-15v-478754.jpg?v=1780496701"},{"product_id":"lop-200-12","title":"LOP-200-12","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMEAN WELL Patent Number: ZL 202223277512.1\u003c\/li\u003e\n\u003cli\u003e4\"x2\" compact size with low profile (25.4mm)\u003c\/li\u003e\n\u003cli\u003e80~264Vac input with PFC, No load power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eGlobal certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1\/-216\u003c\/li\u003e\n\u003cli\u003e150% peak load @ 3s\u003c\/li\u003e\n\u003cli\u003e140W convection, 200W with FAN 10.98CFM forced-cooled\u003c\/li\u003e\n\u003cli\u003esuitable for Class I or Class II installations\u003c\/li\u003e\n\u003cli\u003eOvervoltage category III (OVC III)\u003c\/li\u003e\n\u003cli\u003e-40 ~+80°C wide range operation temperature\u003c\/li\u003e\n\u003cli\u003eHigh efficiency up to 94%\u003c\/li\u003e\n\u003cli\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/li\u003e\n\u003cli\u003eExtremely low leakage current, 2 x MOPP, suitable for BF medical applications\u003c\/li\u003e\n\u003cli\u003eOperating altitude up to 5000 meters\u003c\/li\u003e\n\u003cli\u003eBuilt-in 12V\/0.5A for external FAN\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eVOLTAGE RANGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e80 ~ 264VAC 113 ~ 370VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSETUP, RISE TIME\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1000ms, 30ms\/230VAC 1500ms, 30ms\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eINRUSH CURRENT (Typ.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 40A\/115VAC 80A\/230VAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePOWER FACTOR\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003ePF\u0026gt;0.95\/230VAC PF\u0026gt;0.98\/115VAC at full load\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERLOAD\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 150% rated output power,\u003c\/p\u003e\u003cp\u003eProtection type : Hiccup after 3 sec, recovers automatically(3 sec) after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVERVOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(13.2 - 15.6V) (16.5 - 19.5V) (19.8 - 23.4V) (26.4 - 31.2V) (29.7 - 35.1V) (39.6 - 46.8V) (52.8 - 62.4V) (59.4 - 67.5V)\u003c\/p\u003e\u003cp\u003eProtection type: Shut down o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOVER TEMPERATURE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eProtection type: Shut down o\/p voltage, recovers automatically after temperature goes down or re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003ePROTECTIVE EXTRA-LOW VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIEC\/EN61558-2-16 (SELV, 12~48V )\u003c\/p\u003e\u003cp\u003eIEC\/EN\/UL 62368-1 (SELV \/ ES1,12~48V )\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWORKING TEMP.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e-40 ~ +80℃ (Refer to \"Derating Curve\")\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSAFETY STANDARDS\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCB IEC62368-1, IEC60335-1, IEC61558-1\/-2-16, IEC60601-1; TUV BS EN\/EN62368-1, BS EN\/EN60335-1, BS EN\/EN61558-1\/-2-16, BS EN\/EN60601-1(3.2 Version); UL UL62368-1, ANSI \/ AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS\/NZS 61558-1\/-2-16; EAC TPTC 004 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWITHSTAND VOLTAGE\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:4KVAC I\/P-FG:2KVAC O\/P-FG:1.5KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e101.6x50.8x25.4mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447355752615,"sku":null,"price":64.06,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lop-200-12-200w-42-low-profile-open-frame-power-supply-12v-784136.jpg?v=1780496703"}],"url":"https:\/\/htdelectronics.com\/collections\/low-profile-pcb-type.oembed?page=2","provider":"HTD Electronics","version":"1.0","type":"link"}