{"title":"LCM Series","description":"","products":[{"product_id":"lcm-60u","title":"LCM-60U","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant Current mode output with multiple levels selectable by dip switch\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II design\u003c\/li\u003e\n\u003cli\u003eBuilt-in active PFC function\u003c\/li\u003e\n\u003cli\u003eFunctions: 3 in 1 dimming (dim-to-off);\u003c\/li\u003e\n\u003cli\u003eAuxiliary DC output; synchronization up to 10 units\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC Input Voltage Range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e90 - 132VAC 127 - 186VDC\u003c\/p\u003e\u003cp\u003e(Please refer to \"STATIC CHARACTERISTIC\" section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC Inrush Current (Max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=270μs measured at 50% Ipeak) at 115VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eConstant current limiting, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage Protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 125V\u003c\/p\u003e\u003cp\u003eShutdown o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShutdown o\/p voltage,re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety Standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUL8750 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e123.5x81.5x23mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447265542311,"sku":null,"price":34.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-60u-power-supply-50w-500ma-600ma-700madefault-900ma-1050ma-1400ma-dali-and-push-4215092.jpg?v=1780496436"},{"product_id":"lcm-40u","title":"LCM-40U","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant Current mode output with multiple levels selectable by dip switch\u003c\/li\u003e\n\u003cli\u003ePlastic housing with Class II design\u003c\/li\u003e\n\u003cli\u003eBuilt-in active PFC function\u003c\/li\u003e\n\u003cli\u003eFunctions: 3 in 1 dimming (dim-to-off); Auxiliary DC output; synchronization up to 10 units\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC Input Voltage Range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e180 - 305Vac 255 - 431Vdc\u003c\/p\u003e\u003cp\u003e(Please refer to \"STATIC CHARACTERISTIC\" section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC Inrush Current (Max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=270μs measured at 50% Ipeak) at 115VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eConstant current limiting, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage Protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110 ~ 130V\u003c\/p\u003e\u003cp\u003eShutdown o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShutdown o\/p voltage,re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety Standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUL8750 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e123.5x81.5x23mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447265640615,"sku":null,"price":39.61,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-40u-power-supply-35w-350ma-500ma-600ma-700madefault-900ma-1050ma-dali-and-push-1073699.jpg?v=1780496436"},{"product_id":"lcm-60kn","title":"LCM-60KN","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKNX\/EIB protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eflicker free design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport emergency lighting(EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated constant light output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated KNX push-button interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronization of up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eFunctions: Manual dim, operation hours, power consumption feedback, log\/linear curve selection...etc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~295VAC; 220~392VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting recovers automatically after the fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShutdown o\/p voltage,re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13, BS EN\/EN62384 independent, BIS IS15885(Part2\/Sec13), EAC TP TC 004\napproved, GB19510.14 and GB19510.1(by request) ; According to BS EN\/EN50172, BS EN\/EN 60598-2-22,\nBS EN\/EN61347-2-13 appendix J suitable for emergency installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123.5*81.5*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54pcs\/15Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448343445671,"sku":null,"price":34.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-60kn-power-supply-603w-500ma-600ma-700madefault-900ma-1050ma-1400ma-knx-634026.jpg?v=1780498006"},{"product_id":"lcm-60da2","title":"LCM-60DA2","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency lighting application is available according to IEC61347-2-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eFunctions: DALI interface (logarithm or linear dimming curve selectable), push dimming synchronization up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~295VAC; 254~417VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=270μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting recovers automatically after the fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC; I\/P-DA:1.5KVAC; O\/P-DA:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750(except for DA2-Type), ENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13, BS EN\/EN62384 CSA C22.2 No.250.13-12, independent,GB19510.14, GB19510.1, (except for DA2-Type), EAC TP TC 004 approved; According to BIS IS15885 BS EN\/EN61347 2 13 appendix J suitable for emergency installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123.5*81.5*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54pcs\/15Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448343609511,"sku":"025-651","price":34.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-60da2-power-supply-60w-500ma-600ma-700madefault-900ma-1050ma-1400ma-dali2-and-push-368245.jpg?v=1780498006"},{"product_id":"lcm-60da","title":"LCM-60DA","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency lighting application is available according to IEC61347-2-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eFunctions: DALI interface (logarithm or linear dimming curve selectable), push dimming synchronization up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~295VAC; 254~417VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=270μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting recovers automatically after the fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC; I\/P-DA:1.5KVAC; O\/P-DA:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750(except for DA2-Type), ENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13, BS EN\/EN62384 CSA C22.2 No.250.13-12, independent,GB19510.14, GB19510.1, (except for DA2-Type), EAC TP TC 004 approved; According to BIS IS15885 BS EN\/EN61347 2 13 appendix J suitable for emergency installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123.5*81.5*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54pcs\/15Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448343773351,"sku":null,"price":34.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-60da-ac-dc-multi-stage-led-driver-constant-current-180291.jpg?v=1780498006"},{"product_id":"lcm-60","title":"LCM-60","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlastic housing with class II design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power consumption \u0026lt;1W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eFunctions: 3 in 1 dimming (dim-to-off); Auxiliary DC output; synchronization up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional: Wireless LED driver with integrated EnOcean module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~295VAC; 254~417VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=270μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting recovers automatically after the fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750, CSA C22.2 No.250.13-12, ENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13, BS EN\/EN62384 independent, GB19510.14,GB19510.1,BIS IS15885, EAC TP TC 004 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123.5*81.5*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54pcs\/15Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448343969959,"sku":null,"price":34.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-60-ac-dc-multi-stage-led-driver-constant-current-892132.jpg?v=1780498006"},{"product_id":"lcm-40kn","title":"LCM-40KN","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKNX\/EIB protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eflicker free design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupport emergency lighting(EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated constant light output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated KNX push-button interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSynchronization of up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eFunctions: Manual dim, operation hours, power consumption feedback, log\/linear curve selection...etc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~295VAC; 220~392VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting recovers automatically after the fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShutdown o\/p voltage,re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13, BS EN\/EN62384 independent, BIS IS15885(Part2\/Sec13), EAC TP TC 004 approved, GB19510.14 and GB19510.1(by request) ; According to BS EN\/EN50172, BS EN\/EN 60598-2-22, BS EN\/EN61347-2-13 appendix J suitable for emergency installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123.5*81.5*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54pcs\/15Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448344232103,"sku":null,"price":39.61,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/LCM-40KN.png?v=1780498008"},{"product_id":"lcm-40da2","title":"LCM-40DA2","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency lighting application is available according to IEC61347-2-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eBuilt-in active PFC function and class II design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eFunctions: DALI interface (logarithm or linear dimming curve selectable); push dimming synchronization up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~295VAC; 254~392VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting, recovers automatically after the fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power \u003cimg\u003eon to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC;I\/P-DA:1.5KVAC; O\/P-DA:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750(except for DA2-Type), CSA C22.2 No.250.13-12, ENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13, BS EN\/EN62384 independent, GB19510.14, GB19510.1, BIS IS15885(except for DA2-Type), EAC TP TC 004 approved; According to BS EN\/EN61347-2-13 appendix J suitable for emergency installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123.5*81.5*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54pcs\/15Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448344494247,"sku":"025-650","price":39.61,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/LCM-40DA2.png?v=1780498008"},{"product_id":"lcm-40da","title":"LCM-40DA","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eConstant current mode output with multiple l\u003cimg\u003eevels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmergency lighting application is available according to IEC61347-2-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eBuilt-in active PFC function and class II design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eFunctions: DALI interface (logarithm or linear dimming curve selectable); push dimming synchronization up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~295VAC; 254~392VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting, recovers automatically after the fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC;I\/P-DA:1.5KVAC; O\/P-DA:1.5KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750(except for DA2-Type), CSA C22.2 No.250.13-12, ENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13, BS EN\/EN62384 independent, GB19510.14, GB19510.1, BIS IS15885(except for DA2-Type), EAC TP TC 004 approved; According to BS EN\/EN61347-2-13 appendix J suitable for emergency installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123.5*81.5*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54pcs\/15Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448344723623,"sku":null,"price":39.61,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/LCM-40DA.png?v=1780498010"},{"product_id":"lcm-40","title":"LCM-40","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlastic housing with class II design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power consumption \u0026lt;1W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eFunctions: 3 in 1 dimming (dim-to-off); Auxiliary DC output; synchronization up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional: Wireless LED driver with integrated EnOcean module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~295VAC; 254~417VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting recovers automatically after the fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750, CSA C22.2 No.250.13-12, ENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13, BS EN\/EN62384 independent,GB19510.14,\nGB19510.1, BIS IS15885, EAC TP TC 004 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e123.5*81.5*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e54pcs\/15Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448345051303,"sku":null,"price":39.61,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-40-power-supply-42w-350ma-500ma-600ma-700madefault-900ma-1050ma-dimmable-577613.jpg?v=1780498009"},{"product_id":"lcm-25kn","title":"LCM-25KN","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlastic housing with class II design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power consumption\u0026lt;0.5W(EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eFunctions: 3 in 1 dimming (dim-to-off); synchronization up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~277VAC; 254~392VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting, recovers automatically after fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, recovers automatically after temperature goes down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eENEC EN61347-1, EN61347-2-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105*68*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72pcs\/12.5Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448345215143,"sku":null,"price":25.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-25kn-power-supply-25w-350ma-500ma-600ma-700madefault-900ma-1050ma-knx-955349.jpg?v=1780498011"},{"product_id":"lcm-25da2","title":"LCM-25DA2","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlastic housing with class II design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power consumption\u0026lt;0.5W(EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eFunctions: 3 in 1 dimming (dim-to-off); synchronization up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~277VAC; 254~392VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting, recovers automatically after fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, recovers automatically after temperature goes down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eENEC EN61347-1, EN61347-2-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105*68*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72pcs\/12.5Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448345378983,"sku":"025-1645","price":25.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-25da2-power-supply-25w-350ma-500ma-600ma-700madefault-900ma-1050ma-dali2-and-push-905510.jpg?v=1780498011"},{"product_id":"lcm-25da","title":"LCM-25DA","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlastic housing with class II design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power consumption\u0026lt;0.5W(EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eFunctions: 3 in 1 dimming (dim-to-off); synchronization up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~277VAC; 254~392VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting, recovers automatically after fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, recovers automatically after temperature goes down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eENEC EN61347-1, EN61347-2-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105*68*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72pcs\/12.5Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448345739431,"sku":null,"price":25.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-25da-ac-dc-multi-stage-output-led-driver-active-pfc-626717.jpg?v=1780498012"},{"product_id":"lcm-25","title":"LCM-25","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant current mode output with multiple levels selectable by dip switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlastic housing with class II design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandby power consumption\u0026lt;0.5W(EL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eFunctions: 3 in 1 dimming (dim-to-off); synchronization up to 10 units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180~277VAC; 254~392VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (Typ.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCOLD START 20A(twidth=260μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eShort circuit protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConstant current limiting, recovers automatically after fault condition is removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, recovers automatically after temperature goes down\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms \/ 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P:3.75KVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTcase=-30 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eENEC EN61347-1, EN61347-2-13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C, EN61000-3-3, EAC TP TC 020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105*68*23mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e72pcs\/12.5Kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47448345968807,"sku":null,"price":25.7,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-25-power-supply-25w-350ma-500ma-600ma-700madefault-900ma-1050ma-dimmable-767794.jpg?v=1780498012"}],"url":"https:\/\/htdelectronics.com\/collections\/lcm-series.oembed","provider":"HTD Electronics","version":"1.0","type":"link"}