{"title":"EDR Series","description":"","products":[{"product_id":"edr-75-48","title":"EDR-75-48","description":"","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447329833127,"sku":null,"price":25.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-edr-75-48-single-output-industrial-power-supply-75w-48v-din-rail-996290.jpg?v=1780496616"},{"product_id":"edr-75-24","title":"EDR-75-24","description":"","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447330029735,"sku":null,"price":25.49,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-edr-75-24-single-output-industrial-power-supply-75w-24v-din-rail-439927.jpg?v=1780496617"},{"product_id":"edr-75-12","title":"EDR-75-12","description":"\u003cp data-start=\"14\" data-end=\"744\"\u003eThe EDR-75-12 is a compact 75W industrial DIN rail power supply designed for automation systems, control panels, machinery, and industrial equipment requiring reliable DC power. The unit features a slim metal housing optimized for DIN rail installation and supports a universal AC input range of 90–264VAC. Designed with high efficiency and natural air convection cooling, it provides stable 12VDC output performance while minimizing heat generation. The power supply includes comprehensive protection features such as short circuit, overload, overvoltage, and overtemperature protection for dependable long-term operation. Its rugged design and wide operating temperature range make it suitable for harsh industrial environments.\u003c\/p\u003e\n\u003ch3 data-section-id=\"hz34la\" data-start=\"746\" data-end=\"772\"\u003eGeneral Specifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"774\" data-end=\"1393\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"774\" data-end=\"803\"\u003e\n\u003ctr data-start=\"774\" data-end=\"803\"\u003e\n\u003cth data-start=\"774\" data-end=\"786\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"786\" data-end=\"803\" data-col-size=\"md\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"815\" data-end=\"1393\"\u003e\n\u003ctr data-start=\"815\" data-end=\"836\"\u003e\n\u003ctd data-start=\"815\" data-end=\"823\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"823\" data-end=\"836\"\u003eEDR-75-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"837\" data-end=\"856\"\u003e\n\u003ctd data-start=\"837\" data-end=\"846\" data-col-size=\"sm\"\u003eSeries\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"846\" data-end=\"856\"\u003eEDR-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"857\" data-end=\"879\"\u003e\n\u003ctd data-start=\"857\" data-end=\"872\" data-col-size=\"sm\"\u003ePower Rating\u003c\/td\u003e\n\u003ctd data-start=\"872\" data-end=\"879\" data-col-size=\"md\"\u003e75W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"880\" data-end=\"906\"\u003e\n\u003ctd data-start=\"880\" data-end=\"897\" data-col-size=\"sm\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"897\" data-end=\"906\"\u003e12VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"907\" data-end=\"931\"\u003e\n\u003ctd data-start=\"907\" data-end=\"923\" data-col-size=\"sm\"\u003eRated Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"923\" data-end=\"931\"\u003e6.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"932\" data-end=\"967\"\u003e\n\u003ctd data-start=\"932\" data-end=\"954\" data-col-size=\"sm\"\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"954\" data-end=\"967\"\u003e90–264VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"968\" data-end=\"997\"\u003e\n\u003ctd data-start=\"968\" data-end=\"986\" data-col-size=\"sm\"\u003eInput Frequency\u003c\/td\u003e\n\u003ctd data-start=\"986\" data-end=\"997\" data-col-size=\"md\"\u003e47–63Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"998\" data-end=\"1028\"\u003e\n\u003ctd data-start=\"998\" data-end=\"1021\" data-col-size=\"sm\"\u003eEfficiency (Typical)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1021\" data-end=\"1028\"\u003e87%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1029\" data-end=\"1051\"\u003e\n\u003ctd data-start=\"1029\" data-end=\"1046\" data-col-size=\"sm\"\u003eNo. of Outputs\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1046\" data-end=\"1051\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1052\" data-end=\"1089\"\u003e\n\u003ctd data-start=\"1052\" data-end=\"1069\" data-col-size=\"sm\"\u003eOperation Mode\u003c\/td\u003e\n\u003ctd data-start=\"1069\" data-end=\"1089\" data-col-size=\"md\"\u003eConstant Voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1090\" data-end=\"1132\"\u003e\n\u003ctd data-start=\"1090\" data-end=\"1114\" data-col-size=\"sm\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1114\" data-end=\"1132\"\u003e-20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1133\" data-end=\"1173\"\u003e\n\u003ctd data-start=\"1133\" data-end=\"1150\" data-col-size=\"sm\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1150\" data-end=\"1173\"\u003eFree Air Convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1174\" data-end=\"1219\"\u003e\n\u003ctd data-start=\"1174\" data-end=\"1185\" data-col-size=\"sm\"\u003eMounting\u003c\/td\u003e\n\u003ctd data-start=\"1185\" data-end=\"1219\" data-col-size=\"md\"\u003eDIN Rail TS-35\/7.5 or TS-35\/15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1220\" data-end=\"1255\"\u003e\n\u003ctd data-start=\"1220\" data-end=\"1233\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1233\" data-end=\"1255\"\u003e32 × 125.2 × 102mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1256\" data-end=\"1275\"\u003e\n\u003ctd data-start=\"1256\" data-end=\"1265\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1265\" data-end=\"1275\"\u003e0.51kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1276\" data-end=\"1317\"\u003e\n\u003ctd data-start=\"1276\" data-end=\"1293\" data-col-size=\"sm\"\u003eCertifications\u003c\/td\u003e\n\u003ctd data-start=\"1293\" data-end=\"1317\" data-col-size=\"md\"\u003eUL, TUV, EAC, CE, CB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1318\" data-end=\"1393\"\u003e\n\u003ctd data-start=\"1318\" data-end=\"1331\" data-col-size=\"sm\"\u003eProtection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1331\" data-end=\"1393\"\u003eShort Circuit \/ Overload \/ Over Voltage \/ Over Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447330226343,"sku":"70366","price":25.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-edr-75-12-single-output-industrial-power-supply-75w-12v-din-rail-396111.jpg?v=1780496617"},{"product_id":"edr-150-24","title":"EDR-150-24","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eUniversal AC input \/ Full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCan be installed on DIN rail TS-35 \/ 7.5 or 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eUL508 (industrial control equipment) listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN61000-6-2 (EN50082-2) industrial immunity level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow cost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90~264VAC; 127~370VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 35A at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent adjustment range \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10%~100% rated output current adjustable by 1~10Vdc, PWM signal or resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105%~130% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110%~140% rated output voltage,recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3kVAC, I\/P-FG: 2kVAC, O\/P-FG: 0.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20~+60°C (refer to output derating curve )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL508, TUV EN60950-1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55022(CISPR22) classA, EN61000-3-2,-3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2),EN55024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (screw DIN terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P: 3 poles, O\/P: 4 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH) (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40x 125.2x 113.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47449033572519,"sku":null,"price":31.67,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-edr-150-24-single-output-industrial-power-supply-150w-24v-din-rail-332130.jpg?v=1780500202"},{"product_id":"edr-120-48","title":"EDR-120-48","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eUniversal AC input \/ Full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCan be installed on DIN rail TS35 \/ 7.5 or 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eUL508 (industrial control equipment) listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN61000-6-2 (EN50082-2) industrial immunity level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow cost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty for NDR series \u003cbr\u003e 2 years warranty for EDR series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90~264VAC; 127~370VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 35A at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V: 12~14V, 24V: 24~28V, 48V: 48~55V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent adjustment range \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10%~100% rated output current adjustable by 1~10Vdc, PWM signal or resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105%~130% Constant current limiting, auto-recovery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3kVAC, I\/P-FG: 2kVAC, O\/P-FG: 0.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20~+60!aC (refer to output derating curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL60950-1, TUV EN60950-1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55022 classA, EN61000-3-2(125W for EDR-150),3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (screw DIN terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P: 3 poles, O\/P: 4 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH) (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40x 125.2x 113.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47449033736359,"sku":null,"price":26.02,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-edr-120-48-single-output-industrial-power-supply-120w-48v-din-rail-792074.jpg?v=1780500203"},{"product_id":"edr-120-24","title":"EDR-120-24","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eUniversal AC input \/ Full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCan be installed on DIN rail TS35 \/ 7.5 or 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eUL508 (industrial control equipment) listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN61000-6-2 (EN50082-2) industrial immunity level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow cost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty for NDR series \u003cbr\u003e 2 years warranty for EDR series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90~264VAC; 127~370VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 35A at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V: 12~14V, 24V: 24~28V, 48V: 48~55V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent adjustment range \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10%~100% rated output current adjustable by 1~10Vdc, PWM signal or resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105%~130% Constant current limiting, auto-recovery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3kVAC, I\/P-FG: 2kVAC, O\/P-FG: 0.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20~+60!aC (refer to output derating curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL60950-1, TUV EN60950-1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55022 classA, EN61000-3-2(125W for EDR-150),3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (screw DIN terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P: 3 poles, O\/P: 4 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH) (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40x 125.2x 113.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47449033932967,"sku":"70370","price":25.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-edr-120-24-single-output-industrial-power-supply-120w-24v-din-rail-201499.jpg?v=1780500204"},{"product_id":"edr-120-12","title":"EDR-120-12","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eUniversal AC input \/ Full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Overload \/ Over voltage \/ Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCan be installed on DIN rail TS35 \/ 7.5 or 15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eUL508 (industrial control equipment) listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEN61000-6-2 (EN50082-2) industrial immunity level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow cost\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 years warranty for NDR series \u003cbr\u003e 2 years warranty for EDR series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90~264VAC; 127~370VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 35A at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12V: 12~14V, 24V: 24~28V, 48V: 48~55V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent adjustment range \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10%~100% rated output current adjustable by 1~10Vdc, PWM signal or resistance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105%~130% Constant current limiting, auto-recovery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14V: 14~17V, 24V: 29~33V, 48V: 56~65V Shut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eShut down o\/p voltage, re-power on to recover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3kVAC, I\/P-FG: 2kVAC, O\/P-FG: 0.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20~+60!aC (refer to output derating curve\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL60950-1, TUV EN60950-1 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55022 classA, EN61000-3-2(125W for EDR-150),3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection (screw DIN terminal)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P: 3 poles, O\/P: 4 poles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH) (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e40x 125.2x 113.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47449034096807,"sku":null,"price":26.02,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-edr-120-12-single-output-industrial-power-supply-120w-12v-din-rail-557974.jpg?v=1780500207"}],"url":"https:\/\/htdelectronics.com\/collections\/edr-series.oembed","provider":"HTD Electronics","version":"1.0","type":"link"}