{"title":"AC\/DC\u003e LED Driver","description":"\u003cp\u003eHigh-efficiency, reliable, and versatile power supplies designed specifically to meet the unique requirements of LED lighting applications. These drivers ensure \u003cstrong\u003econsistent, stable, and optimal performance\u003c\/strong\u003e for a wide range of LED systems, from \u003cstrong\u003eindoor and outdoor lighting to architectural and decorative installations\u003c\/strong\u003e.\u003c\/p\u003e","products":[{"product_id":"dtp-206-u","title":"DTP-206-U","description":"\u003cp\u003eFeatures:\u003cbr\u003e⦁    DALI-2 certified touch panel\u003cbr\u003e⦁    Compliant with IEC-62386-301 push button\u003cbr\u003e⦁    Compliant with IEC-62386-332 feedback\u003cbr\u003e⦁    Compatible for DALI-2 controllers\u003cbr\u003e⦁    Powered by DALI Bus\u003cbr\u003e⦁    Configurable functionality via MEAN WELL DLC-02 software\u003cbr\u003e⦁    Each button can trigger multiple modes:\u003cbr\u003e⦁    Short Click\/Double Click\/Long Press, to trigger scene or grouping functions\u003cbr\u003e⦁    Backlight brightness adjustable\u003cbr\u003e⦁    Touch panel volume adjustable\u003cbr\u003e⦁    5 years warranty\u003cbr\u003eGeneral Specification: \u003cbr\u003eInput Voltage\u003cbr\u003eDALI bus 9.5V~22.5V DC according to IEC62386 regulation\u003cbr\u003eCurrent Consumption\u003cbr\u003eTyp. Current \u0026lt;4mA (at 16V) Inrush Current \u0026lt;10mA\u003cbr\u003eProtocol\u003cbr\u003eDALI-2\u003cbr\u003eDALI Standard\u003cbr\u003eIEC62386-101, 103, 301, 332\u003cbr\u003eButton Event\u003cbr\u003eShort click, Double click, Long press\u003cbr\u003eBacklight\u003cbr\u003eThree adjustable levels: high brightness, low brightness, and off\u003cbr\u003eVolume\u003cbr\u003eOptional to turn on or off\u003cbr\u003eOperating Temperature\u003cbr\u003e-20 - +50 °C\u003cbr\u003eSafety standards\u003cbr\u003eBS EN\/EN61347-1; BS EN\/EN61347-2-11\u003cbr\u003eDimension (LxWxH)\u003cbr\u003e120 x 70 x 26.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447259906215,"sku":null,"price":88.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-dali2-panel-6-keys-u-type-5394790.jpg?v=1780496421"},{"product_id":"dtp-206-e","title":"DTP-206-E","description":"\u003cp\u003eFeatures:\u003cbr\u003e⦁    DALI-2 certified touch panel\u003cbr\u003e⦁    Compliant with IEC-62386-301 push button\u003cbr\u003e⦁    Compliant with IEC-62386-332 feedback\u003cbr\u003e⦁    Compatible for DALI-2 controllers\u003cbr\u003e⦁    Powered by DALI Bus\u003cbr\u003e⦁    Configurable functionality via MEAN WELL DLC-02 software\u003cbr\u003e⦁    Each button can trigger multiple modes:\u003cbr\u003e⦁    Short Click\/Double Click\/Long Press, to trigger scene or grouping functions\u003cbr\u003e⦁    Backlight brightness adjustable\u003cbr\u003e⦁    Touch panel volume adjustable\u003cbr\u003e⦁    5 years warranty\u003cbr\u003eGeneral Specification: \u003cbr\u003eInput Voltage\u003cbr\u003eDALI bus 9.5V~22.5V DC according to IEC62386 regulation\u003cbr\u003eCurrent Consumption\u003cbr\u003eTyp. Current \u0026lt;4mA (at 16V) Inrush Current \u0026lt;10mA\u003cbr\u003eProtocol\u003cbr\u003eDALI-2\u003cbr\u003eDALI Standard\u003cbr\u003eIEC62386-101, 103, 301, 332\u003cbr\u003eButton Event\u003cbr\u003eShort click, Double click, Long press\u003cbr\u003eBacklight\u003cbr\u003eThree adjustable levels: high brightness, low brightness, and off\u003cbr\u003eVolume\u003cbr\u003eOptional to turn on or off\u003cbr\u003eOperating Temperature\u003cbr\u003e-20 - +50 °C\u003cbr\u003eSafety standards\u003cbr\u003eBS EN\/EN61347-1; BS EN\/EN61347-2-11\u003cbr\u003eDimension (LxWxH)\u003cbr\u003e86 x 86 x 26.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447260004519,"sku":null,"price":88.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-dali2-panel-6-keys-e-type-5480273.jpg?v=1780496421"},{"product_id":"dtp-204-u","title":"DTP-204-U","description":"\u003cp\u003eFeatures:\u003cbr\u003e⦁    DALI-2 certified touch panel\u003cbr\u003e⦁    Compliant with IEC-62386-301 push button\u003cbr\u003e⦁    Compliant with IEC-62386-332 feedback\u003cbr\u003e⦁    Compatible for DALI-2 controllers\u003cbr\u003e⦁    Powered by DALI Bus\u003cbr\u003e⦁    Configurable functionality via MEAN WELL DLC-02 software\u003cbr\u003e⦁    Each button can trigger multiple modes:\u003cbr\u003e⦁    Short Click\/Double Click\/Long Press, to trigger scene or grouping functions\u003cbr\u003e⦁    Backlight brightness adjustable\u003cbr\u003e⦁    Touch panel volume adjustable\u003cbr\u003e⦁    5 years warranty\u003cbr\u003eGeneral Specification: \u003cbr\u003eInput Voltage\u003cbr\u003eDALI bus 9.5V~22.5V DC according to IEC62386 regulation\u003cbr\u003eCurrent Consumption\u003cbr\u003eTyp. Current \u0026lt;4mA (at 16V) Inrush Current \u0026lt;10mA\u003cbr\u003eProtocol\u003cbr\u003eDALI-2\u003cbr\u003eDALI Standard\u003cbr\u003eIEC62386-101, 103, 301, 332\u003cbr\u003eButton Event\u003cbr\u003eShort click, Double click, Long press\u003cbr\u003eBacklight\u003cbr\u003eThree adjustable levels: high brightness, low brightness, and off\u003cbr\u003eVolume\u003cbr\u003eOptional to turn on or off\u003cbr\u003eOperating Temperature\u003cbr\u003e-20 - +50 °C\u003cbr\u003eSafety standards\u003cbr\u003eBS EN\/EN61347-1; BS EN\/EN61347-2-11\u003cbr\u003eDimension (LxWxH)\u003cbr\u003e120 x 70 x 26.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447260102823,"sku":null,"price":88.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-dali2-panel-4-keys-u-type-2851766.jpg?v=1780496421"},{"product_id":"dtp-203-e","title":"DTP-203-E","description":"\u003cp\u003eFeatures:\u003cbr\u003e⦁    DALI-2 certified touch panel\u003cbr\u003e⦁    Compliant with IEC-62386-301 push button\u003cbr\u003e⦁    Compliant with IEC-62386-332 feedback\u003cbr\u003e⦁    Compatible for DALI-2 controllers\u003cbr\u003e⦁    Powered by DALI Bus\u003cbr\u003e⦁    Configurable functionality via MEAN WELL DLC-02 software\u003cbr\u003e⦁    Each button can trigger multiple modes:\u003cbr\u003e⦁    Short Click\/Double Click\/Long Press, to trigger scene or grouping functions\u003cbr\u003e⦁    Backlight brightness adjustable\u003cbr\u003e⦁    Touch panel volume adjustable\u003cbr\u003e⦁    5 years warranty\u003cbr\u003eGeneral Specification: \u003cbr\u003eInput Voltage\u003cbr\u003eDALI bus 9.5V~22.5V DC according to IEC62386 regulation\u003cbr\u003eCurrent Consumption\u003cbr\u003eTyp. Current \u0026lt;4mA (at 16V) Inrush Current \u0026lt;10mA\u003cbr\u003eProtocol\u003cbr\u003eDALI-2\u003cbr\u003eDALI Standard\u003cbr\u003eIEC62386-101, 103, 301, 332\u003cbr\u003eButton Event\u003cbr\u003eShort click, Double click, Long press\u003cbr\u003eBacklight\u003cbr\u003eThree adjustable levels: high brightness, low brightness, and off\u003cbr\u003eVolume\u003cbr\u003eOptional to turn on or off\u003cbr\u003eOperating Temperature\u003cbr\u003e-20 - +50 °C\u003cbr\u003eSafety standards\u003cbr\u003eBS EN\/EN61347-1; BS EN\/EN61347-2-11\u003cbr\u003eDimension (LxWxH)\u003cbr\u003e86 x 86 x 26.5mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447260233895,"sku":null,"price":88.41,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-dali2-panel-3-keys-e-type-1949322.jpg?v=1780496421"},{"product_id":"xlg-20-m","title":"XLG-20-M","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant Current mode output(Class I)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWide input range 100~305VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass 2 power unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eNo-load power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP67 rating for indoor or outdoor installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 in-1 dimming function (Isolation design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifetime \u0026gt; 50,000 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90~305VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 50A at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms, 100ms, 12ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+80°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBS EN\/EN62384; UL8750 approved; EAC TP TC 004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95x63x30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24pcs \/ 8.67kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447264231591,"sku":null,"price":17.77,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlg-20-m-21w-500ma-252-42v-constant-current-led-driver-8234397.jpg?v=1780496431"},{"product_id":"xlg-20-l","title":"XLG-20-L","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant Current mode output(Class I)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWide input range 100~305VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass 2 power unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eNo-load power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP67 rating for indoor or outdoor installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 in-1 dimming function (Isolation design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifetime \u0026gt; 50,000 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90~305VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 50A at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms, 100ms, 12ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+80°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBS EN\/EN62384; UL8750 approved; EAC TP TC 004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95x63x30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24pcs \/ 8.67kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447264329895,"sku":null,"price":17.77,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlg-20-l-189w-350ma-324-54v-constant-current-led-driver-7459509.jpg?v=1780496431"},{"product_id":"xlg-20-h","title":"XLG-20-H","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant Current mode output(Class I)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWide input range 100~305VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass 2 power unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eNo-load power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP67 rating for indoor or outdoor installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e3 in-1 dimming function (Isolation design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifetime \u0026gt; 50,000 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90~305VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 50A at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms, 100ms, 12ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+80°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBS EN\/EN62384; UL8750 approved; EAC TP TC 004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95x63x30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24pcs \/ 8.67kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447264788647,"sku":null,"price":17.77,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlg-20-h-21w-700ma-18-30v-constant-current-led-driver-2949742.jpg?v=1780496432"},{"product_id":"lcm-60u","title":"LCM-60U","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant Current mode output with multiple levels selectable by dip switch\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II design\u003c\/li\u003e\n\u003cli\u003eBuilt-in active PFC function\u003c\/li\u003e\n\u003cli\u003eFunctions: 3 in 1 dimming (dim-to-off);\u003c\/li\u003e\n\u003cli\u003eAuxiliary DC output; synchronization up to 10 units\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC Input Voltage Range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e90 - 132VAC 127 - 186VDC\u003c\/p\u003e\u003cp\u003e(Please refer to \"STATIC CHARACTERISTIC\" section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC Inrush Current (Max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=270μs measured at 50% Ipeak) at 115VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eConstant current limiting, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage Protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 ~ 125V\u003c\/p\u003e\u003cp\u003eShutdown o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShutdown o\/p voltage,re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety Standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUL8750 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e123.5x81.5x23mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447265542311,"sku":null,"price":34.59,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-60u-power-supply-50w-500ma-600ma-700madefault-900ma-1050ma-1400ma-dali-and-push-4215092.jpg?v=1780496436"},{"product_id":"lcm-40u","title":"LCM-40U","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant Current mode output with multiple levels selectable by dip switch\u003c\/li\u003e\n\u003cli\u003ePlastic housing with Class II design\u003c\/li\u003e\n\u003cli\u003eBuilt-in active PFC function\u003c\/li\u003e\n\u003cli\u003eFunctions: 3 in 1 dimming (dim-to-off); Auxiliary DC output; synchronization up to 10 units\u003c\/li\u003e\n\u003cli\u003e3 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC Input Voltage Range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e180 - 305Vac 255 - 431Vdc\u003c\/p\u003e\u003cp\u003e(Please refer to \"STATIC CHARACTERISTIC\" section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC Inrush Current (Max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=270μs measured at 50% Ipeak) at 115VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eConstant current limiting, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage Protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110 ~ 130V\u003c\/p\u003e\u003cp\u003eShutdown o\/p voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShutdown o\/p voltage,re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand Voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking Temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-30 ~ +90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety Standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eUL8750 approved\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e123.5x81.5x23mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447265640615,"sku":null,"price":39.61,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lcm-40u-power-supply-35w-350ma-500ma-600ma-700madefault-900ma-1050ma-dali-and-push-1073699.jpg?v=1780496436"},{"product_id":"xlg-320-v-a","title":"XLG-320-V-A","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eWide input range 100~305VAC (Class I)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFull power output at 70~100% constant power mode operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eMetal case with IP67, suitable for outdoor application\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eSurge protection with 6KV\/4KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3 in 1 dimming function (Dim to off and isolation design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eProtection functions: OVP\/SCP\/OCP\/OTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifetime \u0026gt; 50,000 hrs. and 5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100~305VAC;142~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 45A at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102%~111% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms, 100ms, 12ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+85°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750 approved; ENEC BS EN\/EN61347-1; EAC TP TC 004; NOM-058-SCFI-2017; IP67 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e246x77x39.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9pcs \/ 14kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447272587431,"sku":"025-116","price":56.98,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/Meanwell_XLG-320-V-A.webp?v=1780496471"},{"product_id":"elg-75-48-3y","title":"ELG-75-48-3Y","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100~305VAC wide input range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in active PFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eProtections: Short circuit \/ Over voltage\/Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh efficiency up to 91%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for LED lighting and street lighting applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100~305VAC;142~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 50 at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110%~140% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+80°C (refer to output derating curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, GB17743,GB17625.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180x63x35.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16pcs \/ 13.4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447272915111,"sku":null,"price":34.09,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-elg-75-48-power-supply-75w-48v-3-wire-input-597419.jpg?v=1780496471"},{"product_id":"elg-75-12da-3y","title":"ELG-75-12DA-3Y","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100~305VAC wide input range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in active PFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eProtections: Short circuit \/ Over voltage\/Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh efficiency up to 91%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for LED lighting and street lighting applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100~305VAC;142~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 50 at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110%~140% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+80°C (refer to output derating curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, GB17743,GB17625.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e180x63x35.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16pcs \/ 13.4kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447273078951,"sku":null,"price":34.09,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-elg-75-12da-power-supply-60w-12v-3-wire-input-dali-960984.jpg?v=1780496470"},{"product_id":"elg-240-48da-3y","title":"ELG-240-48DA-3Y","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100~305VAC wide input range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in active PFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eProtections: Short circuit \/ Over voltage\/Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh efficiency up to 93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for LED lighting and street lighting applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100~305VAC;142~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 75 at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110%~140% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+80°C (refer to output derating curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, GB17743,GB17625.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e244x71x37.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12pcs \/ 15.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447273242791,"sku":null,"price":59.22,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-elg-240-48da-power-supply-240w-48v-3-wire-input-dali-213623.jpg?v=1780496472"},{"product_id":"elg-200-12a-3y","title":"ELG-200-12A-3Y","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100~305VAC wide input range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in active PFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eProtections: Short circuit \/ Over voltage\/Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh efficiency up to 93%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for LED lighting and street lighting applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100~305VAC;142~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 65 at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110%~140% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+80°C (refer to output derating curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, GB17743,GB17625.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e244x71x37.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12pcs \/ 15.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447273406631,"sku":null,"price":55.37,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-elg-200-12a-power-supply-192w-12v-3-wire-input-adjustable-378735.jpg?v=1780496472"},{"product_id":"elg-150-12b-3y","title":"ELG-150-12B-3Y","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100~305VAC wide input range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in active PFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eProtections: Short circuit \/ Over voltage\/Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh efficiency up to 92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for LED lighting and street lighting applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100~305VAC;142~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 65 at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110%~140% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+80°C (refer to output derating curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, GB17743,GB17625.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e219x63x35.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16pcs \/ 16.0kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447273701543,"sku":null,"price":47.6,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/71edSInlvLL.jpg?v=1780496474"},{"product_id":"elg-100-48da-3y","title":"ELG-100-48DA-3Y","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100~305VAC wide input range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in active PFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eProtections: Short circuit \/ Over voltage\/Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh efficiency up to 92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for LED lighting and street lighting applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100~305VAC;142~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 40 at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110%~140% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+80°C (refer to output derating curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, GB17743,GB17625.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e199x63x35.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16pcs \/ 14.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447273865383,"sku":null,"price":43.48,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-elg-100-48da-power-supply-96w-48v-3-wire-input-dali-145145.jpg?v=1780496473"},{"product_id":"elg-100-48-3y","title":"ELG-100-48-3Y","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e100~305VAC wide input range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in active PFC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eProtections: Short circuit \/ Over voltage\/Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo load power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eHigh efficiency up to 92%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for LED lighting and street lighting applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100% full load burn-in test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100~305VAC;142~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 40 at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110%~140% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+80°C (refer to output derating curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11, GB17743,GB17625.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e199x63x35.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16pcs \/ 14.2kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447273996455,"sku":null,"price":43.48,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-elg-100-48-power-supply-96w-48v-3-wire-input-352934.jpg?v=1780496475"},{"product_id":"xlc-60-h-mas","title":"XLC-60-H-MAS","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch (H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5% (H-type)\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100-305VAC 155-400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START VAC NEMA 15A(twidth=310μs measured at 50% Ipeak) at 230 ; Per 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105~200% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (26-35V) (52-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90 (Please refer to “ vs ” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCSA ENEC BS EN EN BS EN EN EL C22.2 No. 250.13-12; \/ 61347-1, \/ 61347-2-13( ) appendix J suitable for emergency installations ( input 176-280 ); \/ 62384 , , 004 approved; DC VDC BS EN EN EAC TP TC GB\/T 19510.1, GB\/T 19510.213 Design refer to \/ 61347-1, \/ 61347-2-13\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176*45*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447274160295,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-mas-led-driver-60w-1400ma-954v-constant-power-current-setting-by-dip-switch-matter-wireless-dimming-with-strain-relief-4583709.jpg?v=1780496474"},{"product_id":"xlc-60-h-ma","title":"XLC-60-H-MA","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch (H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5% (H-type)\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100-305VAC 155-400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START VAC NEMA 15A(twidth=310μs measured at 50% Ipeak) at 230 ; Per 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105~200% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (26-35V) (52-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90 (Please refer to “ vs ” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCSA ENEC BS EN EN BS EN EN EL C22.2 No. 250.13-12; \/ 61347-1, \/ 61347-2-13( ) appendix J suitable for emergency installations ( input 176-280 ); \/ 62384 , , 004 approved; DC VDC BS EN EN EAC TP TC GB\/T 19510.1, GB\/T 19510.213 Design refer to \/ 61347-1, \/ 61347-2-13\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e136*45*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447274389671,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-ma-led-driver-60w-1400ma-954v-constant-power-current-setting-by-dip-switch-matter-wireless-dimming-5258273.jpg?v=1780496477"},{"product_id":"xlc-60-48-mas","title":"XLC-60-48-MAS","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch (H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5% (H-type)\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100-305VAC 155-400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START VAC NEMA 15A(twidth=310μs measured at 50% Ipeak) at 230 ; Per 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105~200% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (26-35V) (52-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90 (Please refer to “ vs ” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCSA ENEC BS EN EN BS EN EN EL C22.2 No. 250.13-12; \/ 61347-1, \/ 61347-2-13( ) appendix J suitable for emergency installations ( input 176-280 ); \/ 62384 , , 004 approved; DC VDC BS EN EN EAC TP TC GB\/T 19510.1, GB\/T 19510.213 Design refer to \/ 61347-1, \/ 61347-2-13\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176*45*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447274520743,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-48-mas-led-driver-60w-48v-constant-voltage-led-driver-matter-wireless-dimming-with-strain-relief-7079743.jpg?v=1780496478"},{"product_id":"xlc-60-48-ma","title":"XLC-60-48-MA","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch (H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5% (H-type)\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100-305VAC 155-400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START VAC NEMA 15A(twidth=310μs measured at 50% Ipeak) at 230 ; Per 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105~200% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (26-35V) (52-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90 (Please refer to “ vs ” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCSA ENEC BS EN EN BS EN EN EL C22.2 No. 250.13-12; \/ 61347-1, \/ 61347-2-13( ) appendix J suitable for emergency installations ( input 176-280 ); \/ 62384 , , 004 approved; DC VDC BS EN EN EAC TP TC GB\/T 19510.1, GB\/T 19510.213 Design refer to \/ 61347-1, \/ 61347-2-13\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e136*45*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447274717351,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-48-ma-led-driver-60w-48v-constant-voltage-led-driver-matter-wireless-dimming-6246971.jpg?v=1780496478"},{"product_id":"xlc-60-24-mas","title":"XLC-60-24-MAS","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch (H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5% (H-type)\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100-305VAC 155-400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START VAC NEMA 15A(twidth=310μs measured at 50% Ipeak) at 230 ; Per 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105~200% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (26-35V) (52-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90 (Please refer to “ vs ” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCSA ENEC BS EN EN BS EN EN EL C22.2 No. 250.13-12; \/ 61347-1, \/ 61347-2-13( ) appendix J suitable for emergency installations ( input 176-280 ); \/ 62384 , , 004 approved; DC VDC BS EN EN EAC TP TC GB\/T 19510.1, GB\/T 19510.213 Design refer to \/ 61347-1, \/ 61347-2-13\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176*45*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447274881191,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-24-mas-led-driver-60w-24v-constant-voltage-led-driver-matter-wireless-dimming-with-strain-relief-7815762.jpg?v=1780496478"},{"product_id":"xlc-60-24-ma","title":"XLC-60-24-MA","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch (H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5% (H-type)\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100-305VAC 155-400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START VAC NEMA 15A(twidth=310μs measured at 50% Ipeak) at 230 ; Per 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105~200% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (26-35V) (52-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90 (Please refer to “ vs ” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCSA ENEC BS EN EN BS EN EN EL C22.2 No. 250.13-12; \/ 61347-1, \/ 61347-2-13( ) appendix J suitable for emergency installations ( input 176-280 ); \/ 62384 , , 004 approved; DC VDC BS EN EN EAC TP TC GB\/T 19510.1, GB\/T 19510.213 Design refer to \/ 61347-1, \/ 61347-2-13\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e136*45*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447275045031,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-24-ma-led-driver-60w-24v-constant-voltage-led-driver-matter-wireless-dimming-2956388.jpg?v=1780496480"},{"product_id":"xlc-60-12-mas","title":"XLC-60-12-MAS","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch (H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5% (H-type)\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100-305VAC 155-400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START VAC NEMA 15A(twidth=310μs measured at 50% Ipeak) at 230 ; Per 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105~200% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (26-35V) (52-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90 (Please refer to “ vs ” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCSA ENEC BS EN EN BS EN EN EL C22.2 No. 250.13-12; \/ 61347-1, \/ 61347-2-13( ) appendix J suitable for emergency installations ( input 176-280 ); \/ 62384 , , 004 approved; DC VDC BS EN EN EAC TP TC GB\/T 19510.1, GB\/T 19510.213 Design refer to \/ 61347-1, \/ 61347-2-13\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176*45*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447275241639,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-12-mas-led-driver-60w-12v-constant-voltage-led-driver-matter-wireless-dimming-with-strain-relief-9184486.jpg?v=1780496480"},{"product_id":"xlc-60-12-ma","title":"XLC-60-12-MA","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch (H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (12\/24\/48V)\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5% (H-type)\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100-305VAC 155-400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START VAC NEMA 15A(twidth=310μs measured at 50% Ipeak) at 230 ; Per 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105~200% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (26-35V) (52-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, re-power on to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90 (Please refer to “ vs ” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCSA ENEC BS EN EN BS EN EN EL C22.2 No. 250.13-12; \/ 61347-1, \/ 61347-2-13( ) appendix J suitable for emergency installations ( input 176-280 ); \/ 62384 , , 004 approved; DC VDC BS EN EN EAC TP TC GB\/T 19510.1, GB\/T 19510.213 Design refer to \/ 61347-1, \/ 61347-2-13\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e136*45*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447275372711,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-12-ma-led-driver-60w-12v-constant-voltage-led-driver-matter-wireless-dimming-3750215.jpg?v=1780496480"},{"product_id":"xlc-40-h-mas","title":"XLC-40-H-MAS","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5%\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100 - 305VAC 141 - 400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 10A(twidth= s measured at 50% Ipeak) at 230VAC 100μ ; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHiccup mode, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eStage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25 ~ 90 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations( DC);   *B2-54!1 BS EN\/EN62384, GB\/T 19510.1, GB\/T 19510.213, EAC TP TC 004 approved ; CSA C22.2 No. 250.13-12 ; Design refer to AS\/NZS 61347-1, AS\/NZS 61347-2-13;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e147*40*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447275569319,"sku":null,"price":39.52,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-40-h-mas-led-driver-40w-1050ma-954v-constant-power-current-setting-by-dip-switch-matter-wireless-dimming-with-strain-relief-5941589.jpg?v=1780496482"},{"product_id":"xlc-40-h-ma","title":"XLC-40-H-MA","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5%\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100 - 305VAC 141 - 400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 10A(twidth= s measured at 50% Ipeak) at 230VAC 100μ ; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eShort Circuit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHiccup mode, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eStage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25 ~ 90 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations( DC);   *B2-54!1 BS EN\/EN62384, GB\/T 19510.1, GB\/T 19510.213, EAC TP TC 004 approved ; CSA C22.2 No. 250.13-12 ; Design refer to AS\/NZS 61347-1, AS\/NZS 61347-2-13;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e107*40*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447275733159,"sku":null,"price":39.52,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-40-h-ma-led-driver-40w-1050ma-954v-constant-power-current-setting-by-dip-switch-matter-wireless-dimming-4607085.jpg?v=1780496482"},{"product_id":"xlc-25-h-mas","title":"XLC-25-H-MAS","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5%\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100 - 305VAC 141 - 400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 10A(twidth= s measured at 50% Ipeak) at 230VAC 100μ ; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eShort Ciruit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHiccup mode, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eStage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25 ~ 85 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC), BS EN\/EN62384; GB\/T 19510.1, GB\/T 19510.213; EAC TP TC 004 approved; ; CSA C22.2 No. 250.13-12 Design refer to AS\/NZS 61347-1, AS\/NZS 61347-2-13 ;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e147*40*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447275896999,"sku":null,"price":36.53,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-25-h-mas-led-driver-25w-700ma-954v-constant-power-current-setting-by-dip-switch-matter-wireless-dimming-with-strain-relief-891729.jpg?v=1780496482"},{"product_id":"xlc-25-h-ma","title":"XLC-25-H-MA","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stage selectable by DIP switch\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker free, complying with CE ErP directive\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.5%\u003c\/li\u003e\n\u003cli\u003eMatter over thread, Matter 1.3 specification\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e100 - 305VAC 141 - 400VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 10A(twidth= s measured at 50% Ipeak) at 230VAC 100μ ; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eShort Ciruit\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eHiccup mode, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eStage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P: 3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25 ~ 85 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC), BS EN\/EN62384; GB\/T 19510.1, GB\/T 19510.213; EAC TP TC 004 approved; ; CSA C22.2 No. 250.13-12 Design refer to AS\/NZS 61347-1, AS\/NZS 61347-2-13 ;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e107*40*32mm (L*W*H)\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447276060839,"sku":null,"price":36.53,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-25-h-ma-led-driver-25w-700ma-954v-constant-power-current-setting-by-dip-switch-matter-wireless-dimming-738804.jpg?v=1780496483"},{"product_id":"lpf-40-20","title":"LPF-40-20","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e \u003cmeta charset=\"utf-8\"\u003e\n\u003c\/h2\u003e\n\u003ch2\u003e\u003cb\u003e\u003cspan\u003eThis is a tested open box model in perfect working condition, see the product name for description of the conditions\u003c\/span\u003e\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003ctable width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eUniversal AC input (up to 305VAC) \/ Full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in active PFC function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eFully isolated plastic case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in 3 in 1 dimming function (1~10VDC, PWM signal or resistance) for D type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eFully encapsulated with IP67 level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass 2 power unit \/ Pass LPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eIsolation class II, no F.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Over current \/ Over voltage \/ Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eSuitable for LED lighting and moving sign applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for dry, damp, and wet location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90~305VAC ; 127~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOver current protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% ~108% constant current, auto-recovery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110%~150% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P - O\/P: 3.75kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+70ºC (refer to output derating curve)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750, ENEC EN61347-1, EN61347-2-13, EN62384, PSE J61347-1, J61347-2-13 approved for LPF-16(D)\/25(D); UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved for LPF-40(D)\/60(D)\/90(D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61547, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL rated, SJTW 18AWGx2C (30cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL rated, SVT 18AWGx2C (30cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e162.5x 43x 32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447280943271,"sku":null,"price":25.15,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lpf-40-20-power-supply-40w-20v-open-box-556377.jpg?v=1780496495"},{"product_id":"lpf-16d-42","title":"LPF-16D-42","description":"\u003ch2\u003e\u003cb\u003e\u003cspan\u003eThis is a tested open box model in perfect working condition, see the product name for description of the conditions\u003c\/span\u003e\u003c\/b\u003e\u003c\/h2\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eUniversal AC input (up to 305VAC) \/ Full range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in active PFC function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eFully isolated plastic case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in 3 in 1 dimming function (1~10VDC, PWM signal or resistance) for D type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eIP30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass 2 power unit \/ Pass LPS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eIsolation class II, no F.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtections: Short circuit \/ Over current \/ Over voltage \/ Over temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eSuitable for LED lighting and moving sign applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuitable for dry, damp, and wet location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003eCooling by free air convection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification\u003c\/h2\u003e\n\u003ctable width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90~305VAC ; 127~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 45A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eOver current protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e95% ~108% constant current, auto-recovery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOver voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110%~150% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P - O\/P: 3.75kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35~+70ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750, ENEC EN61347-1, EN61347-2-13, EN62384, PSE J61347-1, J61347-2-13 approved for LPF-16(D)\/25(D); UL8750, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved for LPF-40(D)\/60(D)\/90(D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61547, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2,3,4,5,6,8,11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Input\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL rated, SJTW 18AWGx2C (30cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL rated, SJTW 18AWGx4C (30cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)(mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e148x 40x 32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447281205415,"sku":null,"price":23.24,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-lpf-16d-42-power-supply-16w-42v-dimmable-open-box-913752.jpg?v=1780496495"},{"product_id":"xlg-50-a","title":"XLG-50-A","description":"\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e Features\u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eConstant power mode output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMetal housing design with functional ground\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eBuilt-in active PFC function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClass 2 power unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eNo old \/ standby power consumption \u0026lt;0.5W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP67 rating for indoor or outdoor installations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003eFunction options: output adjustable via potentiometer 3 in 1 dimming function (Dim to off and Isolation design)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLifetime \u0026gt; 50,000 hrs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e5 years warranty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003ch2\u003e\n\u003cem\u003e\u003c\/em\u003e General Specification \u003c\/h2\u003e\n\u003ctable class=\"\" pure-table width=\"\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e90~305VAC;127~431VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAC inrush current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCold start, 50A at 230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eDC adjustment range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±10% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64%~74% rated output voltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSetup, rise, hold up time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500ms, 100ms, 12ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eI\/P-O\/P: 3.75kVAC, I\/P-FG: 2kVAC, O\/P-FG: 1.5kVAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40~+90°C \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL8750 approved; ENEC AS\/NZS IEC BS EN\/EN61347-1; BS EN\/EN62384;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEMC standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eEN55015, EN61000-3-2 class C,EN61000-3-3, EN61000-4-2,3,4,5,6,8,11; NOM-058-SCFI-2017 approved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e105x63x30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\" pure-table-odd\u003e\n\u003ctd\u003e\u003cstrong\u003ePacking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24pcs \/ 10.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\u003cem\u003e\u003c\/em\u003e\u003c\/h2\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447358701735,"sku":null,"price":21.75,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/696e9e36801300edb2a8b98042de2eb2f8f675ea_XLG_50_A.jpg?v=1780496720"},{"product_id":"xlc-60-h-sn","title":"XLC-60-H-SN","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447378460839,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-sn-led-driver-60w-1400ma-954v-constant-power-with-strain-relief-nfc-current-setting-831487.jpg?v=1780496785"},{"product_id":"xlc-60-h-s","title":"XLC-60-H-S","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447378690215,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-s-led-driver-60w-1400ma-954v-constant-power-with-strain-relief-current-setting-by-dip-switch-512252.jpg?v=1780496786"},{"product_id":"xlc-60-h-n","title":"XLC-60-H-N","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447378886823,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-n-led-driver-60w-1400ma-954v-constant-power-nfc-current-setting-216606.jpg?v=1780496788"},{"product_id":"xlc-60-h-da2sn","title":"XLC-60-H-DA2SN","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447379181735,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-da2sn-led-driver-60w-1400ma-954v-constant-power-dali2-push-dimming-with-strain-relief-nfc-current-setting-480319.jpg?v=1780496789"},{"product_id":"xlc-60-h-da2s","title":"XLC-60-H-DA2S","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447379345575,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-da2s-led-driver-60w-1400ma-954v-constant-power-dali2-push-dimming-with-strain-relief-current-setting-by-dip-switch-822290.jpg?v=1780496791"},{"product_id":"xlc-60-h-da2n","title":"XLC-60-H-DA2N","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447379574951,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-da2n-led-driver-60w-1400ma-954v-constant-power-dali2-push-dimming-nfc-current-setting-658343.jpg?v=1780496792"},{"product_id":"xlc-60-h-da2","title":"XLC-60-H-DA2","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447379771559,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-da2-led-driver-60w-1400ma-954v-constant-power-dali2-push-dimming-current-setting-by-dip-switch-285355.jpg?v=1780496794"},{"product_id":"xlc-60-h-bsn","title":"XLC-60-H-BSN","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447379935399,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-bsn-led-driver-60w-1400ma-954v-constant-power-3-in-1-dimming-with-strain-relief-nfc-current-setting-894836.jpg?v=1780496794"},{"product_id":"xlc-60-h-bs","title":"XLC-60-H-BS","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447380164775,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-bs-led-driver-60w-1400ma-954v-constant-power-3-in-1-dimming-with-strain-relief-current-setting-by-dip-switch-271613.jpg?v=1780496795"},{"product_id":"xlc-60-h-bn","title":"XLC-60-H-BN","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447380394151,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-bn-led-driver-60w-1400ma-954v-constant-power-3-in-1-dimming-nfc-current-setting-520293.jpg?v=1780496795"},{"product_id":"xlc-60-h-b","title":"XLC-60-H-B","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447380623527,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-b-led-driver-60w-1400ma-954v-constant-power-3-in-1-dimming-current-setting-by-dip-switch-845342.jpg?v=1780496796"},{"product_id":"xlc-60-h","title":"XLC-60-H","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447380852903,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-h-led-driver-60w-1400ma-954v-constant-power-current-setting-by-dip-switch-480841.jpg?v=1780496796"},{"product_id":"xlc-60-48-s","title":"XLC-60-48-S","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447381049511,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-48-s-led-driver-60w-48v-with-strain-relief-841556.jpg?v=1780496798"},{"product_id":"xlc-60-48","title":"XLC-60-48","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447381278887,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-48-led-driver-60w-48v-267365.jpg?v=1780496799"},{"product_id":"xlc-60-24-s","title":"XLC-60-24-S","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447381508263,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-24-s-led-driver-60w-24v-with-strain-relief-497557.jpg?v=1780496799"},{"product_id":"xlc-60-24","title":"XLC-60-24","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447381704871,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-24-led-driver-60w-24v-495903.jpg?v=1780496800"},{"product_id":"xlc-60-12-s","title":"XLC-60-12-S","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447381901479,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-12-s-led-driver-60w-12v-with-strain-relief-455029.jpg?v=1780496800"},{"product_id":"xlc-60-12","title":"XLC-60-12","description":"\u003ch2 id=\"features\"\u003eFeatures:\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eConstant power mode output with multiple stages selectable by dip switch or NFC setting(H-type)\u003c\/li\u003e\n\u003cli\u003eConstant voltage mode output (12V\/24V\/48V)\u003c\/li\u003e\n\u003cli\u003ePlastic housing with class II\/2 and PFC design\u003c\/li\u003e\n\u003cli\u003eFlicker-free, complying with IEEE1789\/ErP\u003c\/li\u003e\n\u003cli\u003eStandby power consumption \u0026lt;0.5W\u003c\/li\u003e\n\u003cli\u003eMeet emergency lighting (EL) function application\u003c\/li\u003e\n\u003cli\u003eMinimum dimming level 0.1% (DALI-2 DT6)\u003c\/li\u003e\n\u003cli\u003eDimming functions: 3 in 1 dimming (Dim-to-off) DALI-1 + Push dimming\u003c\/li\u003e\n\u003cli\u003e5 years warranty\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2 id=\"general-specification\"\u003eGeneral Specification\u003c\/h2\u003e\u003cp\u003e\u003cstrong\u003eAC input voltage range\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e110-305VAC 155-431VDC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eAC inrush current (max.)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eCOLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOverload protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e105 - 150% rated output power\u003c\/p\u003e\u003cp\u003eProtection type: Hiccup mode, which recovers automatically after the fault condition is removed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver-voltage protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e(14-17V) (27-35V) (56-63V)\u003c\/p\u003e\u003cp\u003eShut down output voltage, and re-power it to recover\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOver temperature protection\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eShut down output voltage, recovers automatically after fault condition is removed\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWithstand voltage\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eI\/P-O\/P:3.75KVAC\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWorking temperature\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eTcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSafety standards\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eENEC BS EN\/EN61347-1, BS EN\/EN61347-2-13(EL) appendix J suitable for emergency installations; BS EN\/EN62384 independent, GB19510.14, GB19510.1, EAC TP TC 004 approved;\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDimension (LxWxH)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e176x45x32mm , 136x45x32mm\u003c\/p\u003e","brand":"MEAN WELL","offers":[{"title":"Default Title","offer_id":47447382065319,"sku":null,"price":48.87,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/files\/mean-well-xlc-60-12-led-driver-60w-12v-987341.jpg?v=1780496800"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0681\/4675\/7799\/collections\/Mean_Well_HLG_Series_LED_Power_Supplies__36933_bda1c5da-1923-4cb3-a78e-1cf46d2c4381.webp?v=1780497286","url":"https:\/\/htdelectronics.com\/collections\/ac-dc-led-driver.oembed?page=80","provider":"HTD Electronics","version":"1.0","type":"link"}